path ds3 t1 clock source
Syntax
path pathChannel ds3 ds3Channel t1 t1Channel clock source
{
line | internal { module | chassis } }
no path pathChannel ds3 ds3Channel t1 t1Channel clock source
Release Information
Command introduced before JUNOSe Release
7.1.0.
Description
Configures the transmit clock source for a T1 channel
on a DS3 signal. This command applies to a T1 channel on a DS3 over
channelized SONET interface. The no version
restores the default value, line.
Options
-
pathChannel—Number, in the
range 1–2147483648, that identifies the path
-
ds3Channel—Number, in the
range 1–3, that identifies the DS3 channel
-
t1Channel—One or more individual
T1 channels, ranges of T1 channels, or combination of individual channels
and ranges, in the range 1–28 (no spaces); for example, 3,7-15,19-13,27
- line—Interface transmits data from a clock recovered
from the line’s receive data stream
- internal—Interface transmits data using its internal
clock. You must specify one of the following for internal clocking:
- module—Internal clock is from the line module itself
- chassis—Internal clock is from the configured system
clock